![KFA6-DU-Ex1.D Pepperl Fuchs Switch Amplifier [KFA6-DU-Ex1.D]](images/KFA6-DU-Ex1.D.png)
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfa6-du-ex1d-pepperl-fuchs-switch-amplifier-p-5431.html
![KFA6-ER-Ex1.W.LB Pepperl Fuchs Switch Amplifier [KFA6-ER-Ex1.W.LB]](images/KFA5-SOT2-Ex2.png)
1-channel isolated barrier, 230 V AC supply, Level sensing input, Adjustable range 1 k ... 150 k, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfa6-er-ex1wlb-pepperl-fuchs-switch-amplifier-p-5432.html
![KFA6-SOT2-Ex2 Pepperl Fuchs Switch Amplifier [KFA6-SOT2-Ex2]](images/KFA5-SR2-Ex2.W.IR.png)
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfa6-sot2-ex2-pepperl-fuchs-switch-amplifier-p-5424.html
![KFA6-SR2-Ex1.W Pepperl Fuchs Switch Amplifier [KFA6-SR2-Ex1.W]](images/KFA6-SR2-Ex1.W.png)
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/kfa6-sr2-ex1w-pepperl-fuchs-switch-amplifier-p-5411.html
![KFA6-SR2-Ex1.W.LB Pepperl Fuchs Switch Amplifier [KFA6-SR2-Ex1.W.LB]](images/KFD2-ER-Ex1.W.LB img.png)
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/kfa6-sr2-ex1wlb-pepperl-fuchs-switch-amplifier-p-5425.html
![KFA6-SR2-Ex2.W Pepperl Fuchs Switch Amplifier [KFA6-SR2-Ex2.W]](images/KFA6-SR2-Ex2.W-1.jpg)
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/kfa6-sr2-ex2w-pepperl-fuchs-switch-amplifier-p-5412.html
![KFA6-SR2-Ex2.W.IR Pepperl Fuchs Switch Amplifier [KFA6-SR2-Ex2.W.IR]](images/KFA6-SR2-Ex2.W img.png)
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfa6-sr2-ex2wir-pepperl-fuchs-switch-amplifier-p-5433.html
![KFD2-DU-Ex1.D Pepperl Fuchs Switch Amplifier [KFD2-DU-Ex1.D]](images/KFD2-DU-Ex1.D img.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfd2-du-ex1d-pepperl-fuchs-switch-amplifier-p-5408.html
![KFD2-ELD-Ex16 Pepperl Fuchs Switch Amplifier [KFD2-ELD-Ex16]](images/KFD2-ELD-Ex16.png)
16-channel isolated barrier, 24 V DC supply (Power Rail), Analog or digtial field device inputs, Monitors leakage current, Fault relay contact output, LED status indication, Test circuit for validation, Parallel connection for easy integration, Conformal coating …
https://www.controlcomponentsinc.com/kfd2-eld-ex16-pepperl-fuchs-switch-amplifier-p-5434.html
![KFD2-ER-Ex1.W.LB Pepperl Fuchs Switch Amplifier [KFD2-ER-Ex1.W.LB]](images/KFD2-ER-Ex1.W.LB img.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 k ... 150 k, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfd2-er-ex1wlb-pepperl-fuchs-switch-amplifier-p-5435.html
![KFD2-SH-Ex1 Pepperl Fuchs Switch Amplifier [KFD2-SH-Ex1]](images/KFD2-SH-Ex1.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849 …
https://www.controlcomponentsinc.com/kfd2-sh-ex1-pepperl-fuchs-switch-amplifier-p-5403.html
![KFD2-SOT2-EX2 Pepperl Fuchs Switch Amplifier [KFD2-SOT2-EX2]](images/products/KFD2_SOT2_EX2_IO.jpg)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Optocoupler, SIL/IEC 61508. …
https://www.controlcomponentsinc.com/kfd2-sot2-ex2-pepperl-fuchs-switch-amplifier-p-4174.html
![KFD2-SOT2-Ex2 Pepperl Fuchs Switch Amplifier [KFD2-SOT2-Ex2]](images/KFD2-ER-Ex1.W.LB img.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot2-ex2-pepperl-fuchs-switch-amplifier-p-5439.html
![KFD2-SOT2-EX2.IO Pepperl Fuchs Switch Amplifier [KFD2-SOT2-EX2.IO]](images/products/KFD2_SOT2_EX2_IO.jpg)
KFD2-SOT2-EX2.IO Pepperl+Fuchs Switch Amplifier. 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Optocoupler, SIL/IEC 61508. …
https://www.controlcomponentsinc.com/kfd2-sot2-ex2io-pepperl-fuchs-switch-amplifier-p-2299.html
![KFD2-SOT2-Ex2.IO Pepperl Fuchs Switch Amplifier [KFD2-SOT2-Ex2.IO]](images/KFD2-SOT2-Ex2.IO.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot2-ex2io-pepperl-fuchs-switch-amplifier-p-5440.html
![KFD2-SOT2-Ex2.IO-Y181008 Pepperl Fuchs Switch Amplifier [KFD2-SOT2-Ex2.IO-Y181008]](images/KFD2-SOT2-Ex2.IO.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation …
https://www.controlcomponentsinc.com/kfd2-sot2-ex2io-y181008-pepperl-fuchs-switch-amplifier-p-5441.html
![KFD2-SOT3-Ex1.LB Pepperl Fuchs Switch Amplifier [KFD2-SOT3-Ex1.LB]](images/KFD2-SOT3-Ex1.LB.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot3-ex1lb-pepperl-fuchs-switch-amplifier-p-5404.html
![KFD2-SOT3-Ex1.LB.IO Pepperl Fuchs Switch Amplifier [KFD2-SOT3-Ex1.LB.IO]](images/KFD2-SOT3-Ex1.LB.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot3-ex1lbio-pepperl-fuchs-switch-amplifier-p-5405.html
![KFD2-SOT3-Ex2 Pepperl Fuchs Switch Amplifier [KFD2-SOT3-Ex2]](images/KFD2-SOT3-Ex2.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot3-ex2-pepperl-fuchs-switch-amplifier-p-5417.html
![KFD2-SOT3-Ex2.IO Pepperl Fuchs Switch Amplifier [KFD2-SOT3-Ex2.IO]](images/KFD2-SOT3-Ex2.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot3-ex2io-pepperl-fuchs-switch-amplifier-p-5406.html