Results meeting the search terms ""
![IDEC PS5R-VE24 90 Watts 24V DC [PS5R-VE24]](images/products/PS5R_VD24.jpg)
IDEC PS5R-VE24 Power Supply Din Rail Mount 90W 24VDC Universal Input 85-264VAC;100-370VDC …
https://www.controlcomponentsinc.com/idec-ps5r-ve24-90-watts-24v-dc-p-4864.html
![IDEC PS5R-VF24 120 Watts 24V DC [PS5R-VF24]](images/products/PS5R_VD24.jpg)
IDEC PS5R-VF24 Power Supply Din Rail Mount 120W 24VDC Universal Input 85-264VAC;100-370VDC …
https://www.controlcomponentsinc.com/idec-ps5r-vf24-120-watts-24v-dc-p-4863.html
![IDEC RSCDN-20A SSR [RSCDN-20A]](images/IDEC RSCDN20.jpg)
IDEC RSCDN-20A Solid State Relay. 4-32VDC input 20A DIN rail or panel mounting …
https://www.controlcomponentsinc.com/idec-rscdn-20a-ssr-p-5584.html
![IDEC RSCDN-30A SSR [RSCDN-30A]](images/RSCDN-30A.jpg)
IDEC RSCDN-30A Solid State Relay. 4-32VDC input 20A DIN rail or panel mounting …
https://www.controlcomponentsinc.com/idec-rscdn-30a-ssr-p-5585.html
![IDENTControl RFID Control Interface for 2 Read/Write Heads [IC-KP2-2HB17-2V1D]](images/b232874a.png)
IDENTControl Compact control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocols. Connect of to 2 read/write heads …
https://www.controlcomponentsinc.com/identcontrol-rfid-control-interface-for-2-readwrite-heads-p-5388.html
![KCD2-SON-Ex1 Pepperl Fuchs Switch Amplifier [KCD2-SON-Ex1]](images/KFD2-ER-Ex1.W.LB img.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-son-ex1-pepperl-fuchs-switch-amplifier-p-5426.html
![KCD2-SON-Ex2.SP Pepperl Fuchs Switch Amplifier [KCD2-SON-Ex2.SP]](images/KFD2-ER-Ex1.W.LB img.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-son-ex2sp-pepperl-fuchs-switch-amplifier-p-5415.html
![KCD2-SOT-Ex1.LB Pepperl Fuchs Switch Amplifier [KCD2-SOT-Ex1.LB]](images/KCD2-SOT-Ex1.LB.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sot-ex1lb-pepperl-fuchs-switch-amplifier-p-5418.html
![KCD2-SOT-Ex2 Pepperl Fuchs Switch Amplifier [KCD2-SOT-Ex2]](images/KCD2-SOT-Ex1.LB.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sot-ex2-pepperl-fuchs-switch-amplifier-p-5409.html
![KCD2-SOT-Ex2.SP Pepperl Fuchs Switch Amplifier [KCD2-SOT-Ex2.SP]](images/KCD2-SOT-Ex1.LB.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sot-ex2sp-pepperl-fuchs-switch-amplifier-p-5416.html
![KCD2-SR-Ex2.SP Pepperl Fuchs Switch Amplifier [KCD2-SR-Ex2.SP]](images/KCD2-SR-Ex2.SP img.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sr-ex2sp-pepperl-fuchs-switch-amplifier-p-5419.html
![KCD2-ST-Ex1.LB Pepperl Fuchs Switch Amplifier [KCD2-ST-Ex1.LB]](images/KCD2-SOT-Ex1.LB.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-st-ex1lb-pepperl-fuchs-switch-amplifier-p-5428.html
![KCD2-ST-Ex2 Pepperl Fuchs Switch Amplifier [KCD2-ST-Ex2]](images/KCD2-SOT-Ex1.LB.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-st-ex2-pepperl-fuchs-switch-amplifier-p-5414.html
![KFA5-DU-Ex1.D Pepperl Fuchs Switch Amplifier [KFA5-DU-Ex1.D]](images/KFA5-DU-Ex1.D img.png)
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfa5-du-ex1d-pepperl-fuchs-switch-amplifier-p-5429.html
![KFA5-SOT2-Ex2 Pepperl Fuchs Switch Amplifier [KFA5-SOT2-Ex2]](images/KFA5-SOT2-Ex2.png)
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfa5-sot2-ex2-pepperl-fuchs-switch-amplifier-p-5401.html
![KFA5-SR2-EX1.W Pepperl Fuchs Switch Amplifier [KFA5-SR2-EX1.W]](images/products/KFA5_SR2_EX1_W.jpg)
KFA5-SR2-EX1.W Pepperl+Fuchs Switch Amplifier. 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay, SIL/IEC 61508 …
https://www.controlcomponentsinc.com/kfa5-sr2-ex1w-pepperl-fuchs-switch-amplifier-p-2306.html
![KFA5-SR2-Ex1.W.LB Pepperl Fuchs Switch Amplifier [KFA5-SR2-Ex1.W.LB]](images/KFA5-SOT2-Ex2.png)
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/kfa5-sr2-ex1wlb-pepperl-fuchs-switch-amplifier-p-5410.html
![KFA5-SR2-EX2.W Pepperl+Fuchs Switch Amplifier [KFA5-SR2-EX2.W]](images/products/kfa5_sr2_ex2_w.jpg)
KFA5-SR2-EX2.W Pepperl+Fuchs Switch Amplifier. 2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 103.5-126 V AC , 45-65 Hz, Output: relay, SIL/IEC 61508 …
https://www.controlcomponentsinc.com/kfa5-sr2-ex2w-pepperlfuchs-switch-amplifier-p-2223.html
![KFA5-SR2-Ex2.W Pepperl+Fuchs Switch Amplifier [KFA5-SR2-Ex2.W]](images/KFD2-ER-Ex1.W.LB img.png)
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/kfa5-sr2-ex2w-pepperlfuchs-switch-amplifier-p-5402.html
![KFA5-SR2-Ex2.W.IR Pepperl Fuchs Switch Amplifier [KFA5-SR2-Ex2.W.IR]](images/KFA5-SR2-Ex2.W.IR.png)
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfa5-sr2-ex2wir-pepperl-fuchs-switch-amplifier-p-5430.html