Results meeting the search terms ""

Pepperl+Fuchs KFD0-CC-Ex1 Current/Voltage Converter [KFD0-CC-Ex1]Pepperl+Fuchs KFD0-CC-Ex1 Current/Voltage Converter [KFD0-CC-Ex1]
1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd0-cc-ex1-currentvoltage-converter-p-5450.html
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter [KFD0-TR-Ex1]Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter [KFD0-TR-Ex1]
1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd0-tr-ex1-rtd-converter-p-5456.html
Pepperl+Fuchs KFD0-TT-Ex1 Thermocouple Converter [KFD0-TT-Ex1]Pepperl+Fuchs KFD0-TT-Ex1 Thermocouple Converter [KFD0-TT-Ex1]
1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd0-tt-ex1-thermocouple-converter-p-5457.html
Pepperl+Fuchs KFD2-GUT-Ex1.D Temperature Converter [KFD2-GUT-Ex1.D]Pepperl+Fuchs KFD2-GUT-Ex1.D Temperature Converter [KFD2-GUT-Ex1.D]
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-gut-ex1d-temperature-converter-p-5458.html
Pepperl+Fuchs KFD2-PT2-Ex1 Potentiometer Converter [KFD2-PT2-Ex1]Pepperl+Fuchs KFD2-PT2-Ex1 Potentiometer Converter [KFD2-PT2-Ex1]
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-pt2-ex1-potentiometer-converter-p-5451.html
Pepperl+Fuchs KFD2-PT2-Ex1 Potentiometer Converter [KFD2-PT2-Ex1-Y98312]Pepperl+Fuchs KFD2-PT2-Ex1 Potentiometer Converter [KFD2-PT2-Ex1-Y98312]
1-channel, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-pt2-ex1-potentiometer-converter-p-5463.html
Pepperl+Fuchs KFD2-PT2-Ex1-1 Potentiometer Converter [KFD2-PT2-Ex1-1]Pepperl+Fuchs KFD2-PT2-Ex1-1 Potentiometer Converter [KFD2-PT2-Ex1-1]
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-pt2-ex1-1-potentiometer-converter-p-5459.html
Pepperl+Fuchs KFD2-PT2-Ex1-4 Potentiometer Converter [KFD2-PT2-Ex1-4]Pepperl+Fuchs KFD2-PT2-Ex1-4 Potentiometer Converter [KFD2-PT2-Ex1-4]
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-pt2-ex1-4-potentiometer-converter-p-5461.html
Pepperl+Fuchs KFD2-PT2-Ex1-5 Potentiometer Converter [KFD2-PT2-Ex1-5]Pepperl+Fuchs KFD2-PT2-Ex1-5 Potentiometer Converter [KFD2-PT2-Ex1-5]
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-pt2-ex1-5-potentiometer-converter-p-5452.html
Pepperl+Fuchs KFD2-PT2-Ex1-6 Potentiometer Converter [KFD2-PT2-Ex1-6-Y112844]Pepperl+Fuchs KFD2-PT2-Ex1-6 Potentiometer Converter [KFD2-PT2-Ex1-6-Y112844]
1-channel, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 24 mA, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-pt2-ex1-6-potentiometer-converter-p-5462.html
Pepperl+Fuchs KFD2-UT2-Ex1 Universal Temperature Converter [KFD2-UT2-Ex1]Pepperl+Fuchs KFD2-UT2-Ex1 Universal Temperature Converter [KFD2-UT2-Ex1]
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-ut2-ex1-universal-temperature-converter-p-5460.html
Pepperl+Fuchs KFD2-UT2-Ex2 Universal Temperature Converter [KFD2-UT2-Ex2]Pepperl+Fuchs KFD2-UT2-Ex2 Universal Temperature Converter [KFD2-UT2-Ex2]
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC ... More
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-ut2-ex2-universal-temperature-converter-p-5453.html
Pepperl+Fuchs KFD2-UT2-Ex2-1 Universal Temperature Converter [KFD2-UT2-Ex2-1]Pepperl+Fuchs KFD2-UT2-Ex2-1 Universal Temperature Converter [KFD2-UT2-Ex2-1]
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-ut2-ex2-1-universal-temperature-converter-p-5464.html
Pepperl+Fuchs KFD2-WAC2-Ex1.D Strain Gauge Converter [KFD2-WAC2-Ex1.D]Pepperl+Fuchs KFD2-WAC2-Ex1.D Strain Gauge Converter [KFD2-WAC2-Ex1.D]
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... 20 mA or 0 V ... 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-wac2-ex1d-strain-gauge-converter-p-5454.html